Cell Grading

5V 10A 256 Channels

Charge / Discharge Performance Test

Voltage Testing

Current Rate Test

Cycle Life Test

Charge Retention

Production Equipment
(For Incoming Cylindrical Cells Quality Check)
With universal horizontal loading unloading trays – for Cylindrical Cells

cylindrical Cells

Channel quality

Upto 256 channels

Communication method

RS232, CP/IP protocol

Input power

Three phase four wire system AC380v+-3%, 50Hz

Max. output power

< 23KW

Continuous cycle range

1-1999 times

Sleep time setting range

1-720 minutes

Time measurement resolution

1S

Heat dissipation mode

Cold wind

Current range

50MA-10A:(R) 1 MA

Messaurement accuracy

0.5 %FS+0.5 %RD

Communication mode

RS485 baud rate 57,600

Process set

A maximum of 32 work steps and 256 cycles are set

Charging mode

Constant current, Constant pressure

Charging cut-off condition

Voltage, current, time & capacity

Defensive function

 

Overvoltage, undervoltage, overcurrent, unercurrent & overcapacity etc.

Model no.:

DNA-LIB503-512H

Battery type: Cyclinder cell

18650/21700/26650/32700/ 32138/33140/34189

Fixture center distance

34MM

Support battery height

Adjustable in the range of 65-180mm

Working power

Three- phase five-wire systemAC380 V-+ 10%, 50HZ

Voltage measuring range

0-5V, 1 MV resolution

battery voltage range

Punch 0-4.5v: Discharge 4.5- 2v

Constant voltage range

2.5v-4.5v

Time range

Set it anywhere from 0 to 30,000 minutes

Time accuracy

<=1%

Sampling inpection period

<8S

Minimum frequency of data recording

<8S

Battery sorting

By capacity, time, discharge platform etc.

Data processing  

Data, graphs and loop diagrams