Cell Grading machines
repower prismatic cell grading
Channel quality
40 Channel
Communication method
LAN
Input power
Three Phase Four Wire System: AC380 t 10%, 50Hz
Response Time / Sampling
< 10ms
Heat dissipation mode
cold wind
Channel working mode
Completely Independent
Humidity
< 85% R.H (non condensing)
Auxiliary voltage (Optional)
Range
Accuarcy
Resolution
DC: 0-5V
-t0.05%FS
1mV
Auxiliary temperature (Optional)
Range
Accuarcy
Resolution
-20°C ~ 1 00C
± fC (O”C~80C)
0.1°C
Data Export
Data can be exported as EXCEL, TXT or diagram. Provide charge discharge efficiency, charged discharge curve, voltage, capacity, current-time charcteristic curves, etc.
Curves Type
X- coordinate: total time, charge dischagre capacity, cycle time, voltage, current capacity.
Y- coordinate: total voltage, current, capacity, power, cell temperature (Optional}, end of charge and discharge capacity, etc.
Barcode Scan
Support barcode start and binding test data, classify batteries rapidly and accurately.
- Energy Feedback/ Regenerative Type
- Support Multi-Channel Curve Comparsion
- Support Multi-Channel Parallel Connection
Work Condition Simulation
DCIR Measurement
Pulse Test
Temperature Test
State / Dynamic SOC Test
Charge / Discharge Performance Test
Voltage Testing
Current Rate Test
Cycle Life Test
Charge Retention